Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Colloids Surf B Biointerfaces ; 234: 113705, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38194837

RESUMO

Hollow-core microstructured optical waveguides (HC-MOW) have recently emerged in sensing technologies, including the gas and liquid detection for industrial as well as clinical applications. Antiresonant HC-MOW provide capabilities for applications in refractive index (RI) sensing, while the long optical path for analyte-light interaction in HC-MOW leads to increased sensitivity of sensor based on Raman scattering signal measurements. In this study, we developed a two-in-one sensor device using HC-MOW for RI and Raman scattering detection. The performance of the sensor was evaluated by characterizing protein-copolymer multicomponent colloids, specifically, bovine serum albumin (BSA) and poly(N - vinyl-2 -pyrrolidone-co-acrylic acid) P(VP-AA) nano-sized complexes and microbubbles of the corresponding shell. Monocomponent solutions showed linear dependencies of RI and characteristic Raman peak intensities on mass concentration. Multicomponent Raman sensing of BSA@P(VP-AA) complexes and microbubbles revealed that changes in P(VP-AA) characteristic peak intensities can describe interactions between components needed to produce colloid systems. RI sensing of multicomponent colloids demonstrated linear dependence on total mass concentrations for BSA@P(VP-AA) complexes, while corresponding BSA@P(VP-AA) microbubbles can be detected with concentrations as high as 4.0 × 108 MB/mL. Therefore, the developed two-in-one sensor of RI and Raman scattering can be used the robust characterization of albumin-based colloids designed for therapeutic and diagnostic needs.


Assuntos
Refratometria , Análise Espectral Raman , Coloides
2.
Colloids Surf B Biointerfaces ; 219: 112856, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36150237

RESUMO

Gas-liquid interfaces are reaching a particular interest in biomedicine. Microbubbles, ultrasound contrast agents of clinical routine, gained increasing attention as theranostic platforms due to the preserved acoustic response, drug conjugation capabilities, and applicability in biological barrier opening. A combination of microbubbles and photodynamic therapy agents can enhance the photodynamic effect, yet the evaluation of agent conjugation on microbubble stabilization and photodynamic effect is needed. Hence, two commercially available phthalocyanine photosensitizers - Holosens® (ZnPc) and Photosens® (AlPc) - were coupled with bovine serum albumin before microbubble synthesis. We demonstrated an albumin: phthalocyanine ratio of 1:1 and covalent attachment for ZnPc, a ratio of 1:3 with electrostatic binding for AlPc. Submicron-sized microbubbles (air- and SF6- filled) had a diameter of 0.8 µm. Albumin-phthalocyanine conjugates increased the microbubble concentration and shelf-life stability compared to plain ones. We hypothesized that phthalocyanine fluorescence lifetime values decreased after conjugation with microbubbles due to narrow distance between conjugates in the shell. Agents based on AlPc demonstrated higher photodynamic activity than agents based on ZnPc, and microbubbles preserved acoustic stability in human blood plasma. The biodistribution of AlPc-conjugated microbubbles was evaluated. We conclude that our microbubble platforms demonstrate greater photodynamic activity and prolonged stability for further applications in photodynamic therapy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...